Trading

06 · Architectural Metals

Copper sheet, strip and coil

Imperial values are converted from metric; section and sheet designations stay metric.

Units
PDF page 19

06

Architectural Metals

Weathering steel, brass, bronze, copper and titanium-zinc for façades, roofs, screens and interiors.

AM-CUCopper Sheet, Strip & Coil

Architectural copper for façades, roofing, rainwater systems and interiors.

Grade
(CW024A) · C12200
Standards
EN 1172 · EN 1652 · ASTM B370 / B152
Thickness
0.4–1.0 mm building sheet (EN 1172); thicker to EN 16520.016–0.039 in building sheet (EN 1172); thicker to EN 1652
Sizes
Coil and strip to 1250 mm wide; sheet 1000×2000 mmCoil and strip to 49.2 in wide; sheet 39.4×78.7 in
Tempers
R220 · R240 · R290 (Rm 220–260 · 240–300 · 290–360 MPa)R220 · R240 · R290 (Rm 31.9–37.7 · 34.8–43.5 · 42.1–52.2 ksi)
Finishes
Natural · pre-oxidised · pre-patinated · tinned
NATURALWEATHERED BROWNPRE-OXIDISEDPRE-PATINATED
Copper surface finishes

Applications — typical values; follow the system details

Applications — typical values; follow the system details
ApplicationFormTypical thicknessTemper / note
Façade claddingFlat-lock, cassettes, interlocking panels0.6–1.0 mm0.024–0.039 in
Standing-seam roofingDouble-lock or angle seam0.6–0.7 mm0.024–0.028 inR220 / R240
Rainwater systemsGutters, downpipes, outlets0.6–0.8 mm0.024–0.031 inEN 612 dimensions
Flashings & detailsHand-formed trims and cappings0.6–0.7 mm0.024–0.028 inR220 for tight folds
InteriorsWall panels, ceilings, joinery0.5–1.5 mm0.020–0.059 inLacquer to hold colour
SPECIFY ASAM-CU · Cu-DHP (CW024A) R240 · 0.7 mm × 670 mm coil · natural · EN 1172 · 2 t

Last reviewed 2026-09-26 by the Mulk Trading technical team

Standards referenced: EN 1172, EN 1652, ASTM B370, EN 612

Specifications and ranges are indicative; the quotation, order confirmation and mill certificate are binding.

Enquire about Copper sheet, strip and coil